Poor workmanship

The ceiling joist and batten has been compromised by the installation of the downlight.  Extra support is required to bring it back to original compliance.

Funnily enough the downlight fell through into the hall.

Our building inspector often finds the downlights installed like this.


read more >>
 
Occasio Autralia
Pipe corrosion

Pipes corroding on the hot water system due to a chemical re-action between the copper and the sheeting around the hot water system.  The good thing amongst all of this is that the overflow has been directed into the stormwater system.  Top of the class Mr Plumber. Our building inspections often find this not to be the case and the water is left to flow around the footings.


read more >>
 
Occasio Autralia
Air vents

Air vents must have 100mm clearance from external soil or path heights.

This defect is very common in building inspections.


read more >>
 
Occasio Autralia
Ground movement

Cracking in a straight line along side the house indicates some settling or movement in that area.  This will lead to closer examination of allied surfaces to check for structual cracking in walls and footings.


read more >>
 
Occasio Autralia
T.I.C.W.G

Timber in contact with the ground and damp subfloor area.

The ant capping to the timber stump has been compromised, allowing undetected access to the dwelling.

The moisture in the sub floor is ideal for attracting termites.


read more >>
 
Occasio Autralia
Unfinished work in wet area
The area under the raised vanity has not been completed and there is no waterproofing membrane in place to prevent water penetration to other areas.
read more >>
 
Occasio Autralia
Missing Tiles
Presentation is so important in house sales.  A few feature tiles put back in this area would have made all the difference.
read more >>
 
Occasio Autralia
Decayed Flooring

Poor maintenance has resulted in a leaky bathroom causing major structural damage to the flooring members.

Our building inspector found this in the subfloor area, which is the area that the client had not inspected.  Sometimes it is not very nice in the subfloor area.


read more >>
 
Occasio Autralia
Maybe another solution

The robe doors can only be used when the door to the room is closed as they encrouch into the entry door space.

This may become a safety issue when trying to exit the room in an emergency.

A little forward thinking and this may have been avoided.


read more >>
 
Occasio Autralia
Step cracking
Major step cracking was noted under the window and to various other areas of this property.  A structural engineer was engaged to assess all the cracking and movement noted to this property.
read more >>
 
Occasio Autralia
Damaged Plasterboard

A section of the plasterboard is missing from the bottom of the linen cupboard.

The reason for the damage is unknown.


read more >>
 
Occasio Autralia
Installation defect

Improper and ineffective installation has compromised the vermin proofing and wather proofing of the external wall allowing access to the internal areas.

 


read more >>
 
Occasio Autralia
Pointers to house movement.
The building inspector noted that the soffitt sheets to this property had popped out of the joining strips. This is a good indication of house movement along with other indicators.
read more >>
 
Occasio Autralia
Path dropped
Black soil areas have extreme rates of movement between wet and dry seasons and prolonged drought has caused soil to shrink, dropping the concrete about 70mm for its origional position.
read more >>
 
Occasio Autralia
This is colourfull

A piece of broken fibro for an ant cap with packers scattered like a deck of cards and the bearer is left unsupported. This is but some of the different maintenance ideas our building inspectors find.

 


read more >>
 
Occasio Autralia
Stump spalling
Spalling stumps are fairly typical in older homes.  spallin happens when moisture penetrates to the steel and the steel swells with rust. It has the same effect as the Incredible Hulk and his shirts (for those who remember the Incredible Hulk)
The outher layers literally pop off.
Our building inspectors climb under the house if possible.

read more >>
 
Occasio Autralia
Handy man wiring

Our building inspector reckons every ceiling cavity tells a story about its past history good or bad.  This one has had Uncle Bob add a few extra lights.  This could be a good way to burn the house down Bob. We recommend licenced electricians to carry out any electrical work.  It just may save your life and home.


read more >>
 
Occasio Autralia
Down pipe to nowhere
Rain water dispersla system is designed to take water into underground pipes and be diverted away from the house to the street.  Discharging water next to the house creates soil movement problems and encourages termites into the area.
read more >>
 
Occasio Autralia
External soil height too high

The external soil height was too high against the external garage and the result was that when it rained the garage was flooded.

 


read more >>
 
Occasio Autralia
Timber in Contact with Wall

Thes timber fence is in direct contact with the house wall.

This may allow termites undetected access into the house.

A clear gap of 75mm must be provided for a visual inspection zone with at least 25mm clear of the termite protection barriers.


read more >>
 
Occasio Autralia
Renovation indicators
The new timber and sheets replaced over the bathroom indicate a renovation has taken place.  There may be warrenties applicable with this renovation.
read more >>
 
Occasio Autralia
Rubbish in the subfloor

Damp floor together with cardboard and timber makes for a big lunch for termites.

Rubbish in the subfloor provides a great nesting place for vermin.

This area needs to be cleared of all timber and cardboard.

 


read more >>
 
Occasio Autralia
Leaking Pipe
This is the result of using an angle grinder to cut out for the down pipes.
This has resulted in a large hole which is allowing water to escape onto the ground causing moisture to pond around the footings.  A large tube of sealent may help.

read more >>
 
Occasio Autralia
Breeched Party Wall
The services have breeched the party wall.  This is a major area of concern as this may allow a fire in one appartment to gain access into other areas. 
read more >>
 
Occasio Autralia
Timber replacement

New timber is noted in the ceiling void.  In this case there had been a new bathroom renovation and all warrenties were still in place. 

 


read more >>
 
Occasio Autralia
Carport Support

I can't feel my legs.

Like frost bite on a mountain climber, rust has taken the ends off the structural elements.

This was not the only support on this carport that was rusted out.

 


read more >>
 
Occasio Autralia
Gaps in flashing
Our building inspector climbed into the roof void.
Seeing bright daylight in a dark roof void always rings alarm bells.  The flashing is too low to maintain the water barrier in the roof.  It requires fixing by a licenced roofer.

read more >>
 
Occasio Autralia
Damp Subfloor

External soil levels are higher than the subfloor area which is causing water to pond in this area.

The building inspector noted that a drain had been started but not completed.

This area provides may be enticement for the termites.


read more >>
 
Occasio Autralia
Gable End defect

The complonents do not operate as intended, allowing water penetration to the internal roof area.  This then leads to a whole lot of other problems.

This s a common problem in houses and is often caused by poor work practices during construction.

 


read more >>
 
Occasio Autralia
Silicone tells a tale

Huge dobs of Silicone indicated to our building inspector that there may have been water proofing issues inplace previously in the shower.

The shower area required re waterproofing with approved systems.

 


read more >>
 
Occasio Autralia
Timber Decay

Leaking bath tub has cuased major structural decay to the subfloor timbers. This area was a major defect and urgent rectification was ordered.

Our client did not crawl in to the subfloor area when she was inspecting the property.

She  made sure that was an area that we would look into in our building inspections. 


read more >>
 
Occasio Autralia
Scorched Wall
This timber kitchen looks cute but could have become a potential house fire.  The scorched panelling (especially with a fat fire) wouldn't take too long to get a grip and flare up.
read more >>
 
Occasio Autralia
Rusty Gutter

If you were to take a wager on steel being stronger than leaves, check this out.

Leaves win.


read more >>
 
Occasio Autralia
Illegal connection

If you have one of these at your house, look out because they are going to smoke you out.  Illegal connections are frowned upon by the council and a simple smoke test will see smoke coming out of your downpipes. It is then time to reach for the wallet and start explaining things.


read more >>
 
Occasio Autralia
Distorion of bricks
Slab has moved due to excessive soil movement causing corner bricks to fracture and the expected consequence of the damage is unknow until further information is obtained.  A structural engineer will need to be sourced.
read more >>
 
Occasio Autralia
Evidence of previous mud to stump.

Marks on stump left by previous temite mound attached to the stump.

Mud has been removed but the evidence is still there of termites.


read more >>
 
Occasio Autralia
Incorrect path height

Improper installation height of path around the external damp proof course.

D.P.C.must not be less than 150mm above adjacent ground level, 75mm above the finished surface level of adjacent paved, concrete or landscaped areas that slope away from the base of the walls, and 50mm above areas protected from the weather like verandas, balconys and decks.


read more >>
 
Occasio Autralia
Mould and water stainging
Grey mouldy stains in ceilings are usually an indication of water seepage in the roof area.  A quick look in the ceiling space confirmed bad water proofing had caused the problem many years ago.
read more >>
 
Occasio Autralia
Tile slippage

This is the part of the roof that is not normally visible from the ground.  You won't know there is problem till you have water penitration in the ceiling. Recommend a licenced roofing contractor to inspect and recitfy as required.


read more >>
 
Occasio Autralia
No sill to front door

There is water damage to the front door area which is caused by not having a weatherproofing sill, allowing water penetration and wet rot to establish in the surrounding areas.


read more >>
 
Occasio Autralia
Wet trims
Moisture has been causing paint to lift off on the plaster wall in a wet area room.  Insufficient sealing to the area could be one of the causes.
read more >>
 
Occasio Autralia
Soffitt Gap
There was a slight oversite when this home was built 13 years ago.  Trims are meant to help seal the home from weather and vermin.  When climbing in the ceiliing void the building and pest inspectors found evidence of birds nesting inside the roof space. I wonder what else was living in that nice warm space?
read more >>
 
Occasio Autralia
Ceiling Damp

Grey discolouration in a concentrated area with bubbling in the paint is usually a good indication of water penetration through the roof.

Our building inspector found this was caused by a blocked valley in the roof and it was confirmed by the plumber.


read more >>
 
Occasio Autralia
Moving Driveway
Inappropriate methods of paving have caused this driveway to subside down the slope.
read more >>
 
Occasio Autralia
Defibration

Defibration was noted to some roof timbers.

This is a cellular breakdown of timber caused by the exposure to either salt air or industrial fallout (eg. Motor vehicle gases).This is an extremely slow process and no chemical treatment is applicable.

In rare cases with small diameter timbers like tile battens, defibration can cause timbers to fail over time.

 


read more >>
 
Occasio Autralia
Battens compromised

The structural integrity of the roof has been compromised by the cutting of the roof battens. 

Extra battens are required to support the roof.

 


read more >>
 
Occasio Autralia
Concret Stump

This stump was presented like this on a renovated house by a spec-builder.

He didn't think the building inspection would  find that a piece of wire was holding the stump together and that it was not the correct remedy for a sick stump.


read more >>
 
Occasio Autralia
This is different

The light switch was interfering with the door closing.  Problem solved by checking out a section of the door and voila it closes.

 


read more >>
 
Occasio Autralia
Deck compromised vents
The recent addition of a deck has compromised the air vents.  A clear space of 100mm must be maintained around the air vents.
read more >>
 
Occasio Autralia
Old Black Cable

Old style cabling with unprotected connections were noted to still be in use.  We recommend that this always be assess for safe use by a licenced electrician.


read more >>
 
Occasio Autralia
 
body top
What our Clients say
Joe and Linda
Ray and Judy, we just wanted to pass on our appreciation for the great work you did with our...
more >
Pro-check building inspections
Anne

Hello Ray and Judy,

Just wanted to thank you for your service in getting this inspection...

more >
Pro-check building inspections
Shane Duff

I found the service at Pro Check better than any...

more >
Pro-check building inspections
more testimonials >
body top

Pro-check building inspections
QBSA license no 1116897 Home | Comapny Profile | News | Contact | Terms | Privacy | Admin
All right reserved © Copyright Pro-Check Building Services Pty Ltd 2007 | Powered by ADICD
Master Builder  HIA